{"product_id":"plasma-sterilisation-cabinet-50l","title":"Plasma Sterilisation Cabinet - 50L","description":"\u003ch1\u003e\u003cspan\u003ePlasma Sterilisation Cabinet\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eFast. Safe. Cost-Effective Sterilisation for Veterinary Practice\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Plasma Sterilisation Cabinet is an advanced low-temperature sterilisation system designed specifically for heat and moisture-sensitive veterinary instruments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUtilising reactive plasma technology, the system effectively eliminates microorganisms by disrupting their DNA and RNA structures, providing reliable sterilisation without the need for hazardous chemicals, lengthy cycle times, or specialist ventilation systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOperating at temperatures below 45°C, the Plasma Sterilisation Cabinet is ideal for delicate instruments that cannot withstand traditional high-temperature sterilisation methods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose Plasma Sterilisation?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTraditional Ethylene Oxide (ETO) sterilisation systems can take between 18 and 24 hours to complete a cycle, require specialist ventilation, and utilise potentially hazardous chemicals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Plasma Sterilisation Cabinet offers a modern alternative:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eComplete sterilisation cycle in approximately 90 minutes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating costs from as little as £1 per cycle\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNo hazardous chemicals\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNo toxic residues\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNo specialist ventilation or extraction systems required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnvironmentally friendly operation with zero harmful emissions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSafe for heat and moisture-sensitive instruments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReduced instrument turnaround times\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIncreased equipment availability within practice\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003ePlasma Sterilisation vs Ethylene Oxide (ETO)\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003ePlasma Sterilisation Cabinet\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eEthylene Oxide (ETO)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCycle Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 1.5 Hours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18–24 Hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCost Per Cycle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. £1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. £20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVentilation Required\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHazardous Chemicals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthylene Oxide Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eToxic Residue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePotential Residue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnvironmental Impact\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZero Harmful Emissions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegulated Chemical Emissions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstrument Turnaround\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSame Day\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOften Next Day\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStaff Safety\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Toxic Exposure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional Safety Procedures Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eClinical Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSuitable for a wide range of veterinary and medical instruments including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eFlexible endoscopes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRigid endoscopes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLaparoscopic instruments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrosurgical handpieces and accessories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSurgical forceps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSurgical scissors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSurgical tweezers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptical components\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDelicate diagnostic equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMedical devices manufactured from plastic, silicone, rubber and polymer-based materials\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eVeterinary Hospitals\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquine Practices\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSmall Animal Clinics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReferral Centres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMedical Clinics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResearch Facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLaboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eLow Temperature Sterilisation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOperates below 45°C, making it suitable for delicate instruments and sensitive materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRapid Cycle Times\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete sterilisation in approximately 90 minutes, reducing downtime and increasing equipment availability\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompact Size\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1jerge9\" data-start=\"1918\" data-end=\"1939\"\u003eChamber Volume: 50L\u003c\/li\u003e\n\u003cli data-section-id=\"10fupyt\" data-start=\"1940\" data-end=\"1974\"\u003eChamber Size: 525 × 300 × 320 mm\u003c\/li\u003e\n\u003cli data-section-id=\"199nqjd\" data-start=\"1975\" data-end=\"2010\"\u003eExternal Size: 630 × 470 × 500 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCost Effective\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOperating costs from approximately £1 per cycle help reduce ongoing sterilisation expenses.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eEnvironmentally Friendly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProduces no harmful emissions and requires no specialist extraction systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSafe \u0026amp; Reliable\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo hazardous chemicals, no toxic residues, and no additional aeration periods required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e","brand":"Eastern Endoscopy","offers":[{"title":"Default Title","offer_id":54200485871958,"sku":null,"price":12995.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/6098\/5174\/files\/EE-Steriliser-Cleaning-Cabinet.jpg?v=1781524087","url":"https:\/\/easternendoscopy.co.uk\/products\/plasma-sterilisation-cabinet-50l","provider":"Eastern Endoscopy","version":"1.0","type":"link"}